Specifications
39
Display
Units
FEATURES
COM
Supply voltage: Max. 24V
Output current: Max. 10mA
Output saturation voltage: Max. 0.7V
Output
* Protection diode rating 60V/100mA minimum
Relay circuitry
TD62583
0.01µF
0.01µF
+5V
5K7
5K7
Counter
Counter
Input current: Imax=1mA
Input voltage: H=4 to 24V,
L=Max.1V
Example circuit at external
user equipment: Design so as
to make use of the
open-collector output or relay
output.
Protection
diode*
COM
Supply voltage: Max. 24V
Output current: Max. 10mA
Output saturation voltage: Max. 0.7V
Output
* Protection diode rating 60V/100mA minimum
Relay circuitry
TD62583
0.01µF
0.01µF
+5V
5K7
5K7
Counter
Counter
Input current: Imax=1mA
Input voltage: H=4 to 24V,
L=Max.1V
Example circuit at external
user equipment: Design so as
to make use of the
open-collector output or relay
output.
Protection
diode*
SPECIFICATIONS
6.6
67
(8)
96
91.4
48
44.4
44.4
/54
-IN¬MS
-IN¬MS
)NPUT¬IS¬ACTIVE¬
¬¬WHEN¬,(¬,
03%4
MS
MS
6ARIES¬DEPENDING¬ON¬THE¬GAGE
n
.'
5PPER¬TOLERANCE¬LIMIT
,OWER¬TOLERANCE¬LIMIT
#OUNTING¬DATA
.'
Input / output specifications
1) Compatible plug
MIL type connector FAS-10-17 (YAMAICHI), XG4M-1030-T (OMRON)
2) Pin assignment
* Output from each pin in the Digimatic output mode may differ from those which are described in the table above.
* One end of the I/O cable (2m, optional) consists of separate wires for connection as appropriate. The cable’s F.G
wire (with solderless terminal, green) should be connected to the grounding terminal of the main unit.
3) I/O circuit
1. Output circuit (-NG, GO, +NG)
Transistor is “ON” when the open-collector output is “L”.
2. Input circuit (PSET, HOLD)
Input is valid when the line is “L”.
4)
Timing chart
1. Tolerance judgment output
2. External preset/HOLD
5) Optional I/O cable (2m)
z (suffix): A for 110V, D for 220/230V, E for 240V, DC for China, K for Korea or no suffix for 100V.
Pin No. I/O Description Function Optional I/O cable color
1 COM Connected to the internal GND Light brown/black
2 O +NG Tolerance output: The relevant Light brown/red
3 O GO output terminal falls to L. Yellow/black
4 O -NG At an error display [+NG=-NG=L] Yellow/red
5 I HOLD HOLD input Bright green/black
6 I P.SET PRESET input (to cancel the error) Bright green/red
Other than the above listed shall be unconnected.
Dimensions
Unit: mm
EC Counter
DIN size (96 x 48mm) assembly-type display unit
FEATURES
• Employs the DIN size (96x48mm) and mount-on-panel configuration, which greatly facilitates incorporation into a system.
• Can either produce
tolerance judgment output or Digimatic output.
Order No.
542-007z
Model No. EC-101D
Number of gage inputs 1
Maximum input frequency Depends on the gage head connected
Resolution
0.01mm, 0.001mm (automatically set
depending on the gage.)
Display
6-digit and a negative [-] sign LED (amber,
green, red)
Function Preset, GO/±NG judgment
Output
(selectable)
Tolerance judgment -NG, OK, +NG (open-collector)
Data Digimatic code
Input Control signal Preset, data hold
Power supply Via AC adaptor
Operating temperature 0º to 40º
Dimensions W96 x H48 x D156mm
Optional accessories
936937: SPC cable (1m)
965014: SPC cable (2m)
214938: DC plug PJ-2
C162-155: I/O cable
Compatible gage heads LGD, LGS, ID-C
Mass 220g