Specifications

30
Gage
Heads
Output Signal Specifications


Recommended external I/FLGD side
Vcc
• CK,D ATA
• REQ,ORIG
R1
R1
TrCMOS
input
R2
Vdd
C
74HC14, etc.
For Vcc=5V system
R1, R2=22KΩ±10%
C=330pF±20%
Tr=NPN open-collector or N-channel open drain (2SC2855, etc.)
"L" level output voltage VOL=0.2Vmax. (IOL=10mA, etc.)
"H" level leak current: IIK=2µAmax. (at VOH=5.5V)
d1 d2 d3
ALL "F" Measured value
Unit (mm: 0, inch: 1)
Decimal point (0-5) e.g.0 000000.
1 00000.0
5 00.0000
d4 d5
Sign (+: 0, -: 8)
d6 d7 d8 d9 d10 d11 d12 d13
REQ
CK
DATA
t
7
t6t5
t3 t4t2
t8
t1
ORIG
Absolute origin setting
t10
Completed
t11
active
1. Pin assignments and signals
Compatible socket:
Sumitomo 3M : V Low-Proheader
Model: 7610-5002XX or equivalent
Gage plug External device
socket
*1 : LGD, LGS uses a unique specification.
All others use the common Digimatic output specification (10-pin, square).
*2 : Current consumption of LGD,LGS: Idd=20mA max.
2. I/O electrical specifications
Output terminal format: CK, DATA
N-channel open drain
Maximum output curr
ent: 400μA max. (when Vol=0.4V)
Output withstand voltage:
-0.3V to 7V
Input terminal format: REQ, ORIG
Pull-up CMOS input
Inter
nal power supply voltage: Vdd= 1.35 to 1.65V
Pull-up r
esistance: R1= 10 to 100K
”H” level input voltage: VIH= .1V min.:
“L” level input voltage:
VIL= 0.3V max.
Recommended receiving circuit
Note: Since the power supply voltages are different between the gage side and the
external device side, be sure to use an open collector or open drain circuit.
Do not use CMOS output or the like.
LGSLGDStandard
(for reference)
Note 1: The specifications indicated by an asterisk (*) are applicable only to LGD, LGS. All other
Digimatic output specifications are common to all models.
Note 2:
Read data only when CK is at the “L” level.
Note 3: Do not input REQ signal (fixed at “H”) while the absolute origin is being set (during t11).
Note 4: If t5, t6 and t7 are satisfied and REQ is continuously input, an output is obtained from
LGD, LGS at intervals of approximately 95ms.
Note 5:
Start inputting ORIG and REQ after two or three seconds have elapsed (the estimated
time required for internal circuit/sensor to stabilize) following power-on.
3. Data format
• Data is output as 13-digit (52-bit) based on 4 bits = 1 digit.
• Data is output in order from d1 to d13. Each digit is output in the order of LSB to
MSB.
• Measurement data is output in the order of MSD to LSD.
• The sign, measurement data, decimal position and unit are output in BCD based on
positive logic (0=L, 1=H).
4. Timing chart
Symbol min. max.
*t1 0
μs 2sec
t2 15
μs
t3 100
μs
t4 100
μs
t5 0
μs
*t6
*t7
*t8
Symbol min. max.
*t1 160
μs 85ms
t2 150
μs 180μs
t3 150
μs 180μs
t4 300
μs 330μs
t5 0
μs
*t6 100
μs
*t7 100
μs
*t8
Symbol min. max.
*t1 30
μs 95ms
t2 15
μs
t3 100
μs
t4 100
μs
t5 0
μs
*t6 100
μs
*t7 100
μs
*t8 30ms
Symbol min. max.
*t10 1.5s
*t11 4s
Pin No. Signal I/O Description
1 GND Signal ground
2 DATA Output Measurement data-output terminal
3 CK Output Synchronized clock-output terminal
4*
1
N.C. Not used
5
REQ Input Input for data transmission request from external device
6*
1
ORIG Input Input for absolute-origin setting signal
7*
1
N.C. Not used
8*
1
N.C. Not used
9*
1
+5V Power supply (+5V ±10%)*
2
10*
1
GND(F.G.) Frame ground
Digimatic code