INTRODUCTION: The XPRO human interface is an optional component to the Warner Electric XCTRL control which is providing to the user an easy way to get access to the PID regulation SetPoint. It is generally used with Load cells application when the current Tension needs to be changed when running. It’s offering some display screens which could be setup to show some curves or some other data as the current tension, the real time output voltage.
RATINGS: INSTALLING THE XPRO: Panel Cut Dimensions: Warner Electric • +33 (0) 2 41 21 24 24 P-2099-WE-A4 3
1. INSTALLATION REQUIREMENTS: For easier maintenance, operation, and improved ventilation, be sure to install the GP at least 100 mm [3.94 in.] away from adjacent structures and other equipment. Be sure that the surrounding air temperature and the ambient humidity are within their designated ranges. (Surrounding air temperature: 0 to 50°C, Ambient humidity: 10 to 90%RH, Wet bulb temperature: 39°C max.
2. CONNECTION TO THE XCTRL CONTROL: XPRO Serial Connector: RS232C Connector Connected to XCTRL XPRO Interface. To find it, please refer to the XCTRL service manual section: ‘Touch Screen Installation and Setting’.
3. XPRO SCREENS: 1. Power up screen The following screen is displayed at power on. With touching the screen, we are directed to the Home screen. The firmware version is also displayed. 2. Home screen This screen is the main one which allows the user to select what needs to be displayed. The choice can be made between the Setpoint display and change, the Manual outputs forcing, a Graphical display and a Digital display of the main control values.
3. Graphical screen This screen displays all inputs/outputs of the XCTRL control as well as the setpoint. With pressing the Graph’s title, you are asked to select the signal you want to display. With pushing the Cell 1 rectangle, the below screen allows you to make the selection of the desired signal. With the up or down arrows please select the signal. If the arrow on the left side of the screen is pressed down, you will be directed to a screen which is dedicated to the Setpoint update.
4. Set up Setpoint screen This screen allows you to display and to change the current value of the setpoint. There are actually two ways to change it. After having selected which setpoint you want to modify, the first way to change the value is to use the up/down arrows to increase/decrease it by one. The second way is to push the blinking value. It will then display a new screen integrating a digital keyboard with which you will be able to enter directly the required value. 5.
6. Values Screen This screen is aimed to get an overview, at a glance and in real time, of all key values of the control. To select another value than the one displayed, press on the value you want to change and select the correct one on the screen which has been popped up. With the arrows, select the desired signal you want to display the value. 4. SERIAL PROTOCOL BETWEEN XPRO AND XCTRL CONTROL The set of command between XPRO interface and XCTRL control is available.
Warranty Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one (1) year from the date of original purchase for consumer, commercial or industrial use. This warranty extends only to the original purchaser and is not transferable or assignable without Warner Electric LLC’s prior consent. Warranty service can be obtained in the U.S.A.