Electromagnetic Particle Brakes Model: PRB-H P-223-3 819-0370 Installation Instructions
Table of Contents Introduction Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Installation Instructions . . . . . . . . . . . . . . . . . . . .3 Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Mechanical Data . . . . . . . . . . . . . . . . . . . . . . . . .5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Instructions Mounting Introduction Note: For proper function, mount magnetic particle units horizontally. The PRB-H brake mounts to a vertical surface and the customer's shaft is secured in the input hub of the unit. See Figure 2. Mounting dimensions for the PRB-H can be found on page 6 & 7. Pre-Mounting Note: Unit performance can be affected by prolonged exposure to humid environments. Please store in a dry location.
Electrical Connections To avoid injury (or even death), always make certain all power is off before attempting to install or service the control or any electrical equipment. Maintenance Warner Electric Magnetic Particle brakes operate on DC voltage. Warner Electric offers a full line of AC powered controls to meet the needs of almost every application. The service and installation instructions included with each Warner Electric control show the proper electrical connections for the brake.
Electrical Data Electrical Coil Data (PRB-H) Unit Size Voltage Resistance Amperes Watts Torque Build Up Torque Decay [ohms @ 75° F (25°C)] [@ 75° F (25°C)] [@ 75° F (25°C)] (msec) (msec) 31.6 .760 18.2 138 38 1.2 24 2.5 24 25.6 . 934 22.5 175 40 5 24 19.3 1.24 29.8 194 70 10 24 14.8 1.62 38.9 345 95 20 24 12.5 1.93 46.2 440 120 Note: Build up time equals time for torque to build to approximately 63.2% of steady state value after a step change in voltage.
PRB-H Dimensions L B C D H G 5 mm (.20 in.) E F G A J K I 6 Warner Electric • 800-825-9050 300 mm (11.8 in.
PRB-H Dimensional Data Note: All dimensions are nominal unless otherwise noted. Bore Dimensions Model PRB-1.2H PRB-2.5H PRB-5H PRB-10H PRB-20H A mm (in.) B mm (in.) C mm (in.) D mm (in.) E mm (in.) F mm (in.) G mm (in.) H mm 136 (5.35) 63 (2.48) 42 (1.65) 7 (0.28) 5.5 (0.22) 53 (2.09) 109 (4.29) 136.000 135.960 160 73 47 7.5 6.5 60 124 160.000 (6.30) (2.87) (1.85) (0.30) (0.26) (2.36) (4.88) 159.960 195 84.5 57 8 5 67 149 195.000 (7.68) (3.33) (2.24) (0.31) (0.
Warranty Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one (1) year from the date of original purchase for consumer, commercial or industrial use. This warranty extends only to the original purchaser and is not transferable or assignable without Warner Electric LLC’s prior consent. Warranty service can be obtained in the U.S.A.