MSDS
_____________________________________________________________________________________________
6. ACCIDENTAL RELEASE MEASURES
Personal Precautions
Use personal protective equipment. Keep people away from and upwind of spill/leak.
Environmental Precautions
Prevent product from entering drains.
Methods for Containment
Prevent further leakage or spillage if safe to do so.
Methods for Cleaning Up
Sweep up and shovel into suitable containers for disposal. Clean contaminated surface
thoroughly. Use personal protective equipment.
Other Information
Refer to protective measures listed in Sections 7 and 8.
7. HANDLING AND STORAGE
Handling
In case of rupture: Handle in accordance with good industrial hygiene and safety practice.
Wear personal protective equipment. Avoid contact with skin, eyes and clothing.
Storage
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep in properly labeled
containers. Keep out of the reach of children.
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Exposure Guidelines
Chemical Name ACGIH TLV OSHA PEL NIOSH IDLH
Supplier Trade Secret TWA: 1.5 mg/m
3
TWA: 1 mg/m
3
(vacated) TWA: 1 mg/m
3
IDLH: 10 mg/m
3
TWA: 0.015 mg/m
3
Supplier Trade Secret Ceiling: 2 mg/m
3
(vacated) Ceiling: 2 mg/m
3
Ceiling: 2 mg/m
3
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value. OSHA PEL: Occupational Safety and Health
Administration - Permissible Exposure Limits. NIOSH IDLH: Immediately Dangerous to Life or Health.
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA, 965 F.2d 962
(11th Cir., 1992).
Engineering Measures
Showers
Eyewash stations
Ventilation systems
Personal Protective Equipment
Eye/Face Protection
Tightly fitting safety goggles.
Skin and Body Protection
Protective gloves.
Respiratory Protection
No protective equipment is needed under normal use conditions. If exposure limits are
exceeded or irritation is experienced, ventilation and evacuation may be required.
Hygiene Measures
Handle in accordance with good industrial hygiene and safety practice.
_____________________________________________________________________________________________
Page 3 / 8
Revision Date 16-Aug-2013
1103484