The StickyMat system is designed for installation under tile and stone. For use under
other surfaces, please call Warmup at 1-888-927-6333.
Note: The UL Listing for this product covers use in wet locations for CANADA only. Wet location
installation in United States shall be in accordance with the National Electric Code, NFPA 70 and
any other applicable jurisdictional code and final acceptance is to be made by the Authority
Having Jurisdiction (AHJ).
Thermal Insulation
The insulation levels of a floor will affect both the performance & running costs of the under tile
heating mat. Using the Heating Mat without thermal insulation can take up to 5 hours to heat
a room whereas a system with thermal insulation takes less than an hour.
If the Warmup heating mat is being installed onto a concrete base it is highly recommended
that a layer of insulation is used prior to installing the heating mat. The thermal insulation re-
flects the heat upwards instead of allowing heat to penetrate into the subfloor, greatly improv-
ing the warm-up times & running costs.
The Warmup insulation boards are fixed to the base using screws and tile adhesive. The
thickness of insulation required will depend on whether it is for floor renovation or a new floor.
Heating Mat Selection