Step 8 -
Lay Floor Covering
Other Floor Coverings
Final Steps
Typical “R” Values:
Carpet
1
/2” thick = 1.0 * Please check actual values with manufacturer
Stone & Ceramic /" = 0.04 ,
Laminate
1
/4” = 0.3
Engineered wood
3
/4” = 0.75
Vinyl
1
/8” = 0.1
1
1 2
NOTE: Before installing the
floor finish its suitability for
use with underfloor heating
and its maximum operating
temperature should be checked
against required operating
conditions.
If you are planning to install
wood, carpet or vinyl over
the heater a single layer of
self levelling compound
is required (minimum
thickness: ” above the
membrane) over the heater.
You must ensure that all
heating cables are completely
covered. It is important that
the levelling compound is
suitable for use with the DCM-
PRO system.
When the tiles or levelling
compound has been installed,
conduct another resistance
test to ensure the sensor
and heater have not been
damaged and record in the
control card.
Perimeter strips should be cut
flush with the tiles or levelling
compound using a utility knife.