Step 7 -
Select Floor Covering
For floor finishes other than tiles a single layer of self levelling
compound is required (minimum thickness:
3
/
8
” above the
membrane) over the heater which is suitable for use with underfloor
heating and plastic underlayments. You must ensure the entire
heater, including manufactured joints is encased in the levelling
compound.
NOTE: Before installing the floor finish, its suitability for use with
underfloor heating and its maximum operating temperature should
be checked against required operating conditions.
Tiled Floor Finish - With Warmup Insulation Boards
All Floor Finishes - With
3
/
8
” Self Levelling Compound and Warmup
Insulation Boards
Tiled Floor Finish - Without Warmup Insulation Boards
WARMUP
DCM-PRO
CONCRETE SUBFLOOR AND TILES (with Warmup insulation boards)
©
This drawing is confidential and may not be used, copied or disclosed
to anyone without permission of Warmup Plc. The Copyright of these
drawings remain the property of Warmup Plc. Do not scale from
drawings, all dimensions to be checked on site. The Warmup word and
associated logos are trade marks. © Warmup Plc. 2010 - Regd. TM Nos.
1257757, 4409926, 5265707. E & OE. Registered in England No. 2955213.
TITLE:
SCALE:
DESIGNER:
DATE:
VERSION:
WARMUP PLC, 702 Tudor Estate, Abbey Road, London,NW10 7UW
Tel 0845 034 8270 Fax 0208 453 6869
projects@warmup.com www.warmup.co.uk
WARMUP CASTELLATED MAT SYSTEM
1.2_ A3
06.04.2016
01
AAM
01
_
Subfloor
02
_
¹⁄4” Minimum Thinset
03
_
Warmup Insulation boards
04
_
Thinset layer applied with
¹⁄4” x ¹⁄4” square notch trowel*
05
_
DCM-PRO Fleece membrane
06
_
DCM-PRO Cable
07
_
¹⁄4” Minimum Thinset
08
_
Floor finish. Ceramic Tile
WARMUP
DCM-PRO
CONCRETE SUBFLOOR AND TILES (with Warmup insulation boards)
©
This drawing is confidential and may not be used, copied or disclosed
to anyone without permission of Warmup Plc. The Copyright of these
drawings remain the property of Warmup Plc. Do not scale from
drawings, all dimensions to be checked on site. The Warmup word and
associated logos are trade marks. © Warmup Plc. 2010 - Regd. TM Nos.
1257757, 4409926, 5265707. E & OE. Registered in England No. 2955213.
TITLE:
SCALE:
DESIGNER:
DATE:
VERSION:
WARMUP PLC, 702 Tudor Estate, Abbey Road, London,NW10 7UW
Tel 0845 034 8270 Fax 0208 453 6869
projects@warmup.com www.warmup.co.uk
WARMUP CASTELLATED MAT SYSTEM
1.2_ A3
06.04.2016
01
AAM
01
_
Subfloor
02
_
¹⁄4” Minimum Thinset
03
_
Warmup Insulation boards
04
_
Thinset layer applied with
¹⁄4” x ¹⁄4” square notch trowel*
05
_
DCM-PRO Fleece membrane
06
_
DCM-PRO Cable
07
_
³⁄8” Minimum levelling compound
drainage slope to shower drain**
08
_
¹⁄4” Minimum Thinset
09
_
Floor finish. Ceramic Tile
WARMUP
DCM-PRO
CONCRETE SUBFLOOR AND TILES (with Warmup insulation boards)
©
This drawing is confidential and may not be used, copied or disclosed
to anyone without permission of Warmup Plc. The Copyright of these
drawings remain the property of Warmup Plc. Do not scale from
drawings, all dimensions to be checked on site. The Warmup word and
associated logos are trade marks. © Warmup Plc. 2010 - Regd. TM Nos.
1257757, 4409926, 5265707. E & OE. Registered in England No. 2955213.
TITLE:
SCALE:
DESIGNER:
DATE:
VERSION:
WARMUP PLC, 702 Tudor Estate, Abbey Road, London,NW10 7UW
Tel 0845 034 8270 Fax 0208 453 6869
projects@warmup.com www.warmup.co.uk
WARMUP CASTELLATED MAT SYSTEM
1.2_ A3
06.04.2016
01
AAM
Subfloor
02
_
01
_
Thinset layer applied with
¹⁄4” x ¹⁄4” square notch trowel*
03
_
DCM-PRO Fleece membrane
04
_
DCM-PRO Cable
05
_
¹⁄4” Minimum Thinset
06
_
Floor finish. Ceramic Tile
**This method can be used to create a floor surface suitable for most floor finishes and when
forming a drainage slope within a wetroom.
* Where required, prime the exposed surface in accordance with the thinset instructions.
When installing DCM-PRO Peel and Stick membrane, the surface the membrane is being
applied to must be primed and smooth such that a clean and continuous bond can be
made. If necessary an appropriate /" levelling compound should be applied. Coarse and/
or loose subfloor surfaces will prevent the membrane from forming a continuous bond.
For example; cement coated insulation boards with a raised pattern must have a levelling
compound applied over.