Step 5 -
Layout Planning
Fixing Strip - 120 Volt Spacing Guide
PRODUCT CODE
Cable
Length
()
Peg Spacings & Areas Covered ()
3 Pegs
(3")
4 Pegs
(4")
16 W/² 12 W/²
NADCM-C-120-65
16.7 4 6
NADCM-C-120-130
33.1 8 11
NADCM-C-120-195
49.9 12 17
NADCM-C-120-260
66.3 17 22
NADCM-C-120-325
83.0 21 28
NADCM-C-120-390
99.4 25 33
NADCM-C-120-525
132.8 33 44
NADCM-C-120-655
166.0 42 55
NADCM-C-120-785
199.1 50 66
NADCM-C-120-920
232.2 58 77
NADCM-C-120-1050
265.4 66 88
NADCM-C-120-1180
298.5 75 100
NADCM-C-120-1315
331.6 83 111
NADCM-C-120-1445
364.7 91 122
NADCM-C-120-1575
397.9 99 133
Fixing Strip - 240 Volt Spacing Guide
PRODUCT CODE
Cable
Length
()
Peg Spacings & Areas Covered ()
3 Pegs
(3")
4 Pegs
(4")
16 W/² 12 W/²
NADCM-C-240-195
50.0
13 17
NADCM-C-240-325
83.0
21 28
NADCM-C-240-390
99.4
25 33
NADCM-C-240-525
132.8
33 44
NADCM-C-240-655
166.0
42 55
NADCM-C-240-785
199.1
50 66
NADCM-C-240-920
232.2
58 77
NADCM-C-240-1050
265.4
66 88
NADCM-C-240-1180
298.5
75 100
NADCM-C-240-1310
331.6
83 111
NADCM-C-240-1640
414.6
104 138
NADCM-C-240-1970
497.6
124 166
NADCM-C-240-2300
580.6
145 194
NADCM-C-240-2630
663.2
166 221
NADCM-C-240-2955
746.2
187 249
NADCM-C-240-3240
829.2
207 276
NOTE: When installing the cable using fixing strips, maintain a
minimum 2" perimeter spacing between itself and the perimeter or
any unheated areas.
The standard (UL-Approved minimum) cable to cable spacing when
using fixing strips is 3 pegs (3").