Installation Manual
4ft
(1.2m)
°C
21.5
Wed 15 Feb
12:38PM
22.0 until
12:45pm
22.2
Language
English
°C
21.5
Wed 15 Feb 12:38PM
22.0 until
12:45pm
22.2
1 3
6
5
8
9
4
7
2
MySTRATA_HEAT
1. Isolate the thermostat from the mains supply.
2. Unclip the display from the power base and remove the display
3. DO NOT install the thermostat near a window/door, in direct sunlight or above another
heat generating device (e.g. radiator or TV).
4. Ensure distance from the router to thermostat is not excessive to reduce range or
interference issues.
5. Install a 3-1/2” (89 mm) deep single gang or 2-gang box with mud ring in your
preferred thermostat location. Pull wires (heater, supply and sensor) through gang box
and complete terminal wiring.
6. Insert fixing screws through mounting holes of the power base and tighten. Re-attach
the display to the power base and restore power to the thermostat. Follow the on
screen instructions to set up the system. Once set up a QR Code will appear.
NOTE: The function of Probe 1, Probe 2 from Control/Limit Sensor can be swapped in
Advanced Settings; Sensors & Application.
7. Download the MySTRATA_HEAT App.
Technical Specifications
8. Open the MySTRATA_HEAT App and scan the QR Code on the thermostat screen and
follow the instructions in the App to complete setup.
9. Scan the QR Code for full online user guide
The thermostat must be installed by a qualified electrician in accordance with
National Electrical Code (NEC/CEC)
LOAD L1 & L2 Heater Load Max.15A
(1800W - 120V, 3600W - 240V)
LINE L1 Supply Live (120 V)
LINE L2 Supply Neutral (120 V) /
Supply Live (240 V)
P1 & PC Probe 1 - Floor/Air Control Sensor
(No Polarity)
P2 & PC Probe 2 - Limit Sensor (No Polarity)
WIRING CONNECTIONS
EN
#
Use Case Control Limit Sensor
Cas d’utilisation Contrôle Sonde de limitation
Caso de uso Control Sensor de límite
1
A1
B1
C3
X
2
*
A3
B2
C1
P1 & PC
X
3
A1
B2
C2
P1 & PC
4
A2
B1
C3
P1 & PC
X
5
**
A1
B1
C1
P2 & PC
Thermostat in room
Termostato en la habitación
Thermostat dans la pièce
Thermostat in/out of room
Termostato dentro / fuera de la habitación
Thermostat dans/hors de la pièce
Air temperature schedule
Temperatura del aire programación
Programme de température de l’air
Floor temperature schedule
Programa de temperatura del suelo
Programme de température du sol
Floor limit
Límite del suelo
Limite de sol
Air limit
Límite de aire
Limite de air
No floor limit
Sin límite de suelo
Pas de limite de sol
Thermostat out of room
Termostato fuera de la habitación
Thermostat hors de la pièce
A1
A3
B1
B2
C1
C2
C3
A2
Internal air sensor
Sensor de aire interno
Sonde d’air interne
Recommended when thermostat is out of the
heated room
Recommandé lorsque le thermostat est hors de
la pièce chauffée
Recomendado cuando el termostato está fuera
de la habitación climatizada
Recommended when thermostat is in the
heated room
Recommandé lorsque le thermostat est dans la
pièce chauffée
Recomendado cuando el termostato está en la
habitación climatizada.
Air sensor
Sensor de aire
Sonde d’air
Floor sensor
Sensor de suelo
Sonde de sol
Model
0804-0404-XX
Voltage
110V - 240V AC +/-15% 50Hz/60Hz
Protection
II
Max. Load
15A resistive (120 V - 1800W,
240 V - 3600W)
GFCI
Class A GFCI with 5mA trip level
Rated impulse voltage
4000V
Automatic action
100,000
Disconnection means
1B
Pollution degree
2
Max. Ambient Temperature
40°C / 104°F (T40)
Relative Humidity
80 %
IP Rating
IP30
Sensors
Floor/Air
Sensor Type
NTC10K @ 25°C
Operating Frequency
2401 - 2484MHz
Max. Radio-Frequency Power
Transmitted
20dBm
Compatibility
Electric underfloor heating
Standards
UL-60730-1
UL-60730-2-9
UL-943
CAN/CSA-E60730-1
CAN/CSA-E60730-2-9
CAN/CSA-C22.2 No. 144.1
FCC 47 CFR Part 15, ICES-003
Table 1.0 / Tableau / Tabla 1.0
2
*
5
*
Please see table 1.0 for alternative use cases.