Instructions / Assembly

5
Table 1.0 - Thermostat use cases
# Use Case Control Limit Sensor
1
Thermostat IN room
Air temperature schedule
Nooorlimit
Internal
Air Sensor
None
2
*
Thermostat IN/OUT of room
Floor temperature schedule
Floor limit
P1 & PC
Floor Sensor
None
3
Thermostat IN room
Floor temperature schedule
Air limit
P1 & PC
Floor Sensor
Internal
Air Sensor
4
Thermostat OUT of room
Air temperature schedule
Nooorlimit
P1 & PC
Air Sensor
None
5
**
Thermostat IN room
Air temperature schedule
Floor limit
Internal
Air Sensor
P2 & PC
Floor Limit
6
Thermostat IN/OUT of room
Floor temperature schedule
Floor limit
P1 & PC
Floor Sensor
P2 & PC
Floor Limit
7
Thermostat OUT of room
Air temperature schedule
Floor limit
P1 & PC
Air Sensor
P2 & PC
Floor Limit
8
Thermostat IN/OUT of room
Regulator schedule
No limit
Reg. None
9
Thermostat IN room
Regulator schedule
Air limit
Reg.
Internal
Air Sensor
10
Thermostat IN/OUT of room
Regulator schedule
No limit
Reg. None
11
Thermostat IN/OUT of room
Regulator schedule
Floor limit
Reg.
P2 & PC
Floor Limit
12
Thermostat IN/OUT of room
Regulator schedule
Floor limit
Reg.
P2 & PC
Floor Limit
2
*
Recommended when thermostat is OUT of the heated room
5
**
Recommended when thermostat is IN the heated room
NOTE: For thermostat use cases 6 & 7 an additional sensor will be required.