Instructions / Assembly
3
Safety Information
Step 1 - Installation
The6iEmustbeinstalledbyaqualiedelectrician.Itrequiresa
permanent 110V - 240V AC, 60Hz supply. The 6iE contains a Class A
GFCI with 5mA trip level and wiring must conform to local electrical
code.
Isolate the 6iE from the mains supply throughout the installation
process.
Conduits are only required where it is mandated by state or
provincial code. Please refer to local electrical code for compliant
applications.
The 6iE and its packaging are not toys; do not allow children to
play with them. Small components and packaging present a risk of
chokingorsuocation.
q
q
q
q
The 6iE is suitable for indoor use only. It must not be exposed to
moisture, vibrations, mechanical loads or temperatures outside of its
rated values.
For safety and licensing reasons unauthorised change and/or
modicationofthe6iEisnotpermitted.
Ensure the distance from your router to the 6iE is not excessive.
This will ensure the wireless connection is not subject to range or
interference issues once installed.
Install the 6iE in an area with good ventilation. It should not be
beside a window/door, in direct sunlight or above another heat
generating device (e.g. radiator or TV).
q
q
q
q
Isolate the 6iE and supply from
the mains supply.
Installa3-1/2”(89mm)deepsinglegangor2-gangboxwithmudring
in your preferred thermostat location. Pull wires (heater, supply and
sensor) through gang box and complete terminal wiring.
Unclip the display from the
power base and remove the
display
1
3
2