Instructions / Assembly

14
Settings
Advanced settings Sensors &
Application
Internal Air Sensor Oset
+/- 10°
Probe 1 Connected On/O
Type
5, 10, 15, 100K
Oset
+/- 10°
The 6iE uses a 10K sensor. However, if using
a 6iE to replace an existing thermostat you
must change to the correct sensor type.
Probe 2 Connected On/O
Type
5, 10, 15, 100K
Oset
+/- 10°
Swap Probe Usage
The function of Probe 1, Probe 2 from
Control/ Limit Sensor can be swapped here.
Floor
thermostat
(Probe 1 On, Probe
2 O. See Table
1.0 for alternative
thermostat use
cases)
Control
Floor
Remote Air
Regulator
Limit
None/Air
Choose to switch the method of control for
the sensor; oor sensor, remote air sensor
if not installed underneath the oor or
regulator mode.
Regulator Mode; Heating is on for X% out of
control cycle (default 10mins). Heating is o
for remaining time.
Floor type
*
Tile/Stone
Laminate
Carpet
Wood
Vinyl
Other
Choose the oor type of your installation.
This will apply dierent temperature and
overheat limits to the 6iE.
*
Not applicable if conventional heating
system was selected.
Display, cont’d Night period Set the Start and
End period
This is the time when you usually go to bed at night and wake
up in the morning. The brightness of “Night” mode will begin
and end using this time.
Screen lock On/O
Locks the 6iE screen to prevent any unauthorised changes to
the 6iE. Requires a 4 digit code to access the menu or make
changes.
Advanced Settings