User manual

6
© 2012 OJ Electronics A/S
Type UCG/UDG English
6 Press the Up or Down buttons to select one of the four types of
control:
ROOM: The built-in room sensor is used. Only room temperature is
controlled.
FLOOR: A floor sensor is used. Only floor temperature is controlled.
REGULATOR: The thermostat functions as a simple regulator and no
sensors are used.
ROOM LIMIT: The thermostat controls room temperature while using
the external temperature sensor as a limit sensor. If you choose this
option, you must set a maximum and minimum temperature for the
limit sensor, so that the thermostat will switch the heating o or on
if the temperature on the floor reaches the maximum or minimum
temperature respectively. This can, for instance, be used to avoid
excessively high temperatures on wooden flooring (maximum limit) or
excessively cold temperatures on tiled/stone flooring (minimum limit).
7 Press the OK button.
8 If FLOOR or ROOM LIMIT is chosen, maximum and minimum floor
temperatures can now be set. Press the Up or Down buttons to set
the High temperature. Press OK and set the Low temperature. Press
the OK button.
9 Follow the Exit Menu procedure to exit the menu.
Please note: Usually, the electrician who installed the thermostat will have
selected the correct type of temperature control for your application.
ROOM
FLOOR
REGULATOR
ROOM LIMIT
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
Display
I want to choose the information to be shown on the thermostat
display.
To do so, you must:
1 With Active Display (backlight on) press OK to activate the menu.
2 Press the Up or Down buttons until the SETTINGS option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the DISPLAY option flashes.
5 Press the OK button.
6 Press the Up or Down buttons to select whether or you wish to:
- display the Clock or not (On/O),
- display the Set temperature or not (On/O).
- You can also decide whether the temperature displayed is the Room
temperature, the Floor temperature (if a floor sensor is used) or the
Regulator temperature.
7 Press the OK button to confirm the settings as you work your way
through the various options in the DISPLAY submenu.
8 Follow the Exit Menu procedure to exit the menu.
Factory settings: TIME: ON; SET TEMP.: ON; TEMP.: FLOOR
FLOOR
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
On/O
On/O
Room/floor/regulator
Factory Reset
I want to return to the factory settings.
To do so, you must:
1 With Active Display (backlight on) press OK to activate the menu.
2 Press the Up or Down buttons until the SETTINGS option flashes.
3 Press the OK button.
4 Press the Up or Down buttons until the FACTORY RESET option
flashes.
5 Press the OK button. A submenu will appears.
6 Press the Up or Down buttons until the RESET option flashes.
7 Press the OK button.
8 Follow the Exit Menu procedure to exit the menu.
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
RESET
EXIT
Error Messages
E0 = Internal failure. Replace thermostat.
E1 = Internal sensor defective or short-circuited. Replace thermostat.
E2 = External sensor defective or short-circuited. Check external sensor.
Factory Settings for Automatic 5:2 Program
Days 1-5 (Monday - Friday)
Event Time Temperature
Morning 6:00 a.m. - 8:00 a.m. 77 °F / 25 °C
Out 8:00 a.m. - 4:00 p.m. 68 °F / 20 °C
Home 4:00 p.m. - 10:00 p.m. 77 °F / 25 °C
Night 10:00 p.m. - 6:00 a.m. 68 °F / 20 °C
Days 6-7 (Saturday - Sunday)
Event Time Temperature
Day 8:00 a.m. - 11:00 p.m. 77 °F / 25 °C
Night 11:00 p.m. - 08:00 a.m. 68 °F / 20 °C