Installation Guide

IMPORTANT:
BEFORE STARTING YOUR FLOOR WARMING
PROJECT, PLEASE REVIEW THESE IMPORTANT DO’S AND DON’TS
DON’T
NEVER cut the warming cable
NEVER shorten the warming mat
NEVER connect TWO (2) or more warming mats together in series
NEVER fold or position the warming cable so that it overlaps itself or
other wires (this could cause dangerous overheating)
NEVER run a power lead or sensor wire across the warming cable
NEVER place built-in cabinets or other furniture with solid bases on top
of the heated area of the oor (this could trap heat and cause
dangerous overheating)
NEVER, when laying the system directly on top of a concrete suboor,
lay the warming cable over an expansion joint
NEVER run a warming cable in or through a wall
NEVER lay the warming system closer than 2” from a wall or another
heat source
NEVER connect warming mat to the power supply before it is installed
beneath the oor covering (this could cause dangerous
overheating)
DO
ALWAYS when using timer, connect the system to a dedicated, GFCI
protected, 15 or 20 Amp Circuit (depending on heating area)
ALWAYS test the warming system before, during and after installation
ALWAYS maintain consistent spacing when positioning the
warming cable
ALWAYS make sure that your ooring type is compatible with the
warming system
1