User guide
Troubleshooting
SECTION 8
8.2 Troubleshooting
8.2.1 Locating a Fault in the TempZone™ Floor Heating Cable (Twin)
UseaCircuitCheck™orPowerMan™deviceduringcableinstallation.Thesedeviceswillprovideanaudiblealarmifthe
wireisdamagedorcutduringinstallation.Acontinuitycheckerisnotacceptableforthesetests.
Beware of Using a Continuity Checker!
Withcablesthathaveover200Ωresistance,somecontinuitycheckersdonotsendenoughcurrenttogetcompletely
throughthewireandemitthenoiseorlightthatafrmspropercontinuity.Forthisreason,wealwaysrecommendusinga
digitalohmmeterorPowerMan™foranyproducttestingortroubleshooting.
Aftertheinstallation,ifnecessary,thepositionofabreakcanbefoundwiththeWarmlyYoursTroubleshootingKit.Atime
domainreectometer(ShortStop)willnotbeabletondabreakwithoutaninstallationplan.Repairkitsandguidance
areavailablefromWarmlyYours24/7TechnicalSupportat(800)875-5285,orgotowww.WarmlyYours.com/supportfor
additional information.
23