User guide

8.1 Identify the Problem
Ifthesystemisnotfunctioningproperly,refertothe“QuickReferenceTroubleshootingGuide”todeterminethecauseof
the problem.
Quick Reference Troubleshooting Guide
Ohm Reading What It Indicates What to Do Next
Zero Opencircuitorshort
ObtainShortStopfaultnder*
fromWarmlyYourstocheck
distancetobreak.
Lowerthantheacceptablerange,
butsomecontinuityispresent
Ohmmeterbatteriesmaybelow
Replacebatteriesandtakeohm
readingsagain.
Multipleelectricalshorts
ObtainShortStopfaultnder*
fromWarmlyYours.Takeareading
betweeneachcorewireand
ground to determine the location
oftheshort.
Withinrange(-5/+10%)of
speciedvalueonULlabel
Nobreak Checkforanelectricalshort.
Higher than acceptable range Possibleshort
ObtainShortStopfaultnder*
fromWarmlyYours.Takeareading
betweeneachcorewireand
ground to determine the location
oftheshort.
Innity
OhmmeterorPowerMan™may
besettoincorrectscale
SetohmmeterorPowerMan™
tocorrectscaleandtestagain.
(Correctscalesettings:
0to200Ωforcable;
0to20,000Ωforsensorwire)
Possibleshort
ObtainShortStopfaultnder*
fromWarmlyYours.Takeareading
betweeneachcorewireand
ground to determine the location
oftheshort.
Possiblebreak
ContactWarmlyYoursfor
assistance.
*Note:Aoorplanwiththelayoutoftheinstallationisrequiredtodeterminethelocationoftheshort.
Troubleshooting
SECTION 8
22