5.5.4 Instructions for Installation Under Tile and Stone Flooring
Option 1: Single-layer method for tile and stone
Applyalayerof3/8inchlatex-modiedthinsetcementorself-levelingunderlayment(SLU)overtheheatingcable.Laythe
tileorstonedirectlyintothatlayerofthinsetcement.
OR
Option 2: Double-layer method for tile and stone
Embedtheheatingcableinaskimcoatoflatex-modiedthinsetorself-levelingunderlayment,completelycoveringthe
heatingelementandthesensorwire.Applyasecondlayerofthinsetandlaytilesasusual.Therecommendeddepthfor
bothlayersofthinsetorSLUis3/8inch.
Thesingle-layermethodisusedmostbyexperiencedinstallersinsmallapplicationswitheasyaccess.WarmlyYoursdoes
NOTrecommendthesingle-layermethodforinstallingmosaicsortilesofdifferentsizesorifyouhavenotinstalledan
electricradiantheatingsystemundertileorstonebefore.
WaitingPeriod:Regardlessofmethodused,installationofoorheatingcableundertileorstonerequires2to28days
forthelatex-modiedthinsetorself-levelingunderlaymenttocure.Followmanufacturerrecommendationsforcuretimes
applicabletoyourinstallation.
IMPORTANT: Do NOT turn on the WarmlyYours TempZone™ Floor Heating Cable (Twin) system until after the
thinset or self-leveling underlayment (SLU) has fully cured. Doing so will result in damage to the system
and cause the thinset or SLU to become brittle. Failure of the thinset or SLU may cause damage to the
embedded cable. This type of damage is not covered by the WarmlyYours warranty.
5.5.5 Instructions for Installation Under Carpet (U.S. only), Vinyl, or
Laminated Flooring
BeforeapplyingSLU,ensurethatthecableisrmlysecuredtothesuboortopreventitfromoatingtothetopoftheself-
levelingunderlayment.AttachCircuitCheck™orPowerMan™atthistime.Covercablewith3/8inchlayerofself-leveling
underlayment.