User guide

8.Applythinsetorself-levelingcompoundovertheheatingcableandsuboor.Acrylic,latex,orpolymer-modiedthinset
cementmaybeused.Ensurethatthematerialyouselectiscompatiblewiththeooringmaterial.Contacttheadhesive
manufacturerformoreinformationandcuringtimes.
Ensurethattherearenoairgapsduringapplicationofthinsetorself-levelingunderlayment(SLU).Makesurethe
heatingcable,factorysplices,andlow-voltagethermostatsensor(ifused)arecompletelyembeddedinthethinsetor
SLU.IfSLUisused,besuretouseanyprimerrequiredbythemanufacturer.
Asingle-ordouble-layermethodmaybeusedoveranysuboor(plywood,cementslab,concretebackerboard,or
mudbed).Thesemethodsaresuitableforanystoneortileoorcovering.Forcarpet(U.S.only),vinylorlaminateoor
coverings,WarmlyYoursrecommendscoveringtheoorheatingsystemwith3/8inchofself-levelingunderlayment
(totaldepth,whetherthesingle-ordouble-layerapplicationmethodisused)tocreateasmoothsurfaceforinstalling
thesetypesofooring.Followtheinstructionsappropriatetothetypeofoorcoveringtobeused.
CAUTION: Careless use of the trowel can damage the heating cable. Never drop or bang a trowel directly
on the cable.
5.5.3 Instructions for Installation in Wet Locations
1.InstallationshallbeinaccordancewiththeNationalElectricalCode,NFPA-70andCAN/CSA-C22.1,CanadianElectrical
code(CEC),Part1andthatnalacceptanceistobemadeintheeldbytheAuthorityHavingJurisdiction(AHJ).
2.WarmlyYoursrecommendsusingaseparateheatingcableforshowerareas.Note:TheULListingforthisproductdoes
notcoveruseinwetlocationsintheUnitedStates.InstallationsshallbeinaccordancewiththeNationalElectricCode,
NFPA70andanyotherapplicablejurisdictionalcodesandnalacceptanceistobemadebytheAuthorityHaving
Jurisdiction(AHJ).
3.Ifinsulationboardisbeingusedoveraslab,usesuitableglueorcement-basedadhesive,orthinsetmortartoadhereit
totheslab.Ifinstallinginawetlocation,ensuretheslopeofthemortarbedismaintainedsothatitdirectswatertothe
drainpipe.
Installation and Operation
SECTION 5
16