2.1 General Precautions Before Installation of the TempZone™
Floor Heating Cable
2.1.1 TempZone™FloorHeatingCablemustNOTtouch,crossover,oroverlapitselfatanypoint.
Thiscouldcausethecabletooverheat.UseTempZone™CableFixingStripstoavoidbunchingorcrossoverofthecable.
2.1.2 DoNOTcuttheTempZone™FloorHeatingCable.Alteringthecablelengthmayresultinoverheatinganddamagetothe
cable.Ensurethatyouorderthecorrectcablelengthforyourinstallation.
2.1.3 TakeprecautionstoavoiddamagetotheTempZone™cableduringinstallation.Donotdropsharpobjectsorcarelessly
steponthecable.Donotbangthetrowelontheheatingcablewhileapplyingmortar.
2.1.4 Ifyouarereplacingaoorwithanexistingoorheatingsystem,completelyremoveoldmatsand/orcablebefore
installingnewtheTempZone™FloorHeatingCable.
2.1.5 TempZone™oorheatingcablesshouldbeseparatedfromotherheatsources.PertheNationalElectricCode,section
424.39,heatingelementsofcablesmustbeseparatedatleast200mm(8in)fromtheedgeofoutletboxesandjunction
boxesthataretobeusedformountingsurfaceluminaires.Aclearanceofnotlessthan50mm(2in)shallbeprovided
fromrecessedluminairesandtheirtrims,ventilationopeningsandothersuchopeningsinroomsurfaces.Noheating
cableshallbecoveredbyanysurface-mountedequipment.
2.1.6 DonotinstallTempZone™FloorHeatingCablewhentheambienttemperatureisbelow5ºF(-15ºC).
2.1.7 Ifusingathermalinsulationunderlaymentbetweentheself-levelingunderlayment-encasedcableandthenaloor
covering(verifyinstallationisincompliancewithlocalelectricalcode),useaproductwithatypicalR-valueof0.027
orless.
2.1.8 WarmlyYoursrecommendsusingCeraZorb®underlaymentwheninstallingcableoveraconcreteoororslabtoallowa
greaterpercentageofheatgeneratedtotransfertotheooringsurface.
2.1.9 ThebendingradiusoftheTempZone™FloorHeatingCableduringinstallationshouldnotbelessthan25mm(1in).
2.1.10Thecoldleadis15feetlong.WarmlyYoursrecommendsallowing12inchesofcoldleadwiretoextendfromthe
thermostatboxtofacilitateeasierthermostatconnection.Anyexcesscoldleadmaybetrimmed.Pleasefollowallnational
andlocalelectriccodes.
2.1.11 CentertheoorthermostatsensorbetweentwoadjacentrunsofTempZone™FloorHeatingCable.Donotlocateoor
thermostatsensorcloserthan1inchtothecableorallowittooverlapanyothercable.
2.1.12 Carpetandlaminatemanufacturersmayrecommendamaximumlimitforthetemperaturesettingonthethermostatof
86ºF(30ºC).
2.1.13 DonotinstalltheTempZone™FloorHeatingCableunderpermanentxtures(e.g.cabinets,bathtubs).
2.1.14 Allowforasufcientdryingorcuringperiodofthesuboorandnishedoorcoveringbeforeandafterinstallingthe
TempZone™FloorHeatingCable.DoNOToperateoorheatuntilthethinsetorself-levelingunderlayment(SLU)has
completely cured.
2.1.15Pleasenotethethicknessofthefactoryspliceandcoldleadandplanaccordingly.
2.1.16Whenusingself-levelingunderlayment(SLU),WarmlyYoursrecommendsprimingtheoorbeforeattachingtheCable
FixingStripsandsecuringthecable.Doingsowillensurethattheprimercoversthesuboorcompletely.Wheneverusing
SLU,ALWAYSfollowtheinstallationrecommendationssetforthbytheSLU’smanufacturer.Itisveryimportanttoadhere
theheatingcablesecurelytothesuboor,otherwisetheheatingcablemayoattothetopoftheSLU.
Before You Begin