Instructions / Assembly
5. Once the electric radiant heating system has been installed, test the system
with a digital ohm meter as described in the installation manual. If the system
tests good, run the cold lead up the conduit and into the thermostat box.
6. Once the wires are run up to the thermostat box, install the cable protector
plate so it covers the wires at the bottom plate. This will protect the wires
from stray nails.
6/17/99
Floor Heating
System
Black
Ground
Ground
Black
Yellow
or Red
Yellow
or Red
PAGE 2 / 3
Cold Lead
Floor
Sensor
Drive Strap
Sensor
Protector
Plate
Cold Lead
ENT Tube
Floor
Sensor
7. Place the smurf/ENT tube over the sensor wire to protect
it from the high voltage wires, before attaching sensor to power base.
Installation Support • (800) 875-5285 • www.WarmlyYours.com
Floor Heating Application
Electrical Install Kit with Conduit Installation