Instruction Manual

5
3.1.3. General Information on Positioning
With infrared radiation, improper positioning can result in certain areas of space in a room experiencing a “shadow” effect (similar to a
cloud passing between you and the sun). To prevent shadow effects, the optimal positioning of your infrared heater will mean that there
are no objects between the heater and the area that is to be heated. For detailed information about optimal positioning, please consult
your dealer where you purchased the EMBER panel.
Instructions for Installation
Section 3
3.2. Electrical Connection (Hardwired)
If the Ember plug is removed, a hardwired panel can be controlled, via
a permanent connection, to a suitable room thermostat. Please refer to
the instructions of the room thermostat for proper connections.
Attention: If the power cord of the unit is damaged, it must be
replaced immediately.
Fix mounted thermostats should be mounted next to the heated room’s
entry door at 4’ or 1.3m height from oors. An alternate location is on
an interior wall, not subject to direct sunlight. The thermostat should
not be installed within 3 feet of the EMBER.
Power the thermostat with a GFCI Protected Circuit.
The device is connected with the supplied connector to a junction box
supplying the AC power supply. If a longer cable is required, it can be
replaced by longer one, 18 AWG or larger.
Heating
A hardwired heater can be controlled by an externally
mounted thermostat.
Grounding
The heater is for use with 120 volts. The green-yellow grounding of the
cord must be connected to a permanent ground inside the junction box.
Attention: All permanent electrical connections must be done
according to local electrical codes and be done by a licensed electrican.