Installation manual

ELECTRICAL CONNECTION
The heater is designed for permanent connection to a
suitable room thermostat. Please refer to the instructions
of the room thermostat.
ATTENTION: If the power cord of the unit is damaged, it
must be replaced immediately.
Fix mounted thermostats should be mounted next to the
heated room’s entry door at 4’ or 1.3m height from oors.
An alternate location is on an interior wall, not subject to
direct sunlight. The thermostat should not be installed
within 3 feet of the LAVA. Power the thermostat with a
GFCI Protected Circuit.
The device is connected with the supplied connector to
a junction box supplying the AC power supply. If a longer
cable is required, it can be replaced by longer one, 18 AWG
or Larger.
HEATING
The heater is controlled by the externally mounted
thermostat.
GROUNDING
The heater is for use with 120 volts. The green-yellow
grounding of the cord must be connected to a permanent
ground inside the junction box.
Installation and Usage Instruction | LAVA® Design Glass Radiator
8
WIRING DIAGRAM
FOR 120V LAVA® RADIANT PANELS
WITH THE NSPIRE TOUCH THERMOSTAT (UDG4-4999)
Installation Support •(800) 875-5285 • www.WarmlyYours.com
2” x 4” ELECTRICAL BOX
2” x 4” ELECTRICAL BOX
LAVA RADIANT PANEL
BLACK
POWER
SWITCH
15 AMP
120V
BREAKER
Hot Black
Hot
Black
Neutral
White
Neutral
White
GROUND
(green or yellow)
NEUTRAL LOAD
(white or brown)
ELECTRICAL BREAKER PANEL
WHITE
GREEN
BLACK
WHITE
GREEN
HOT LOAD
(black or blue)
CONSULT LOCAL
ELECTRICAL CODE
CONCERNING DESIRED
LAVA MOUNTING LOCATION
NSPIRE TOUCH
PROGRAMMABLE
TOUCHSCREEN THERMOSTAT
(UDG4-4999)
Ground
Fig 9: Connection diagram