Technical information

31
Combi 70 & Combi 90 Oil Boilers
4 - BOILER INSTALLATION
13 Remove and discard the conventional flue flexible
air tube supplied with the boiler from the burner air
spigot retaining the clamp.
Extend the flexible air tube supplied with the flue
kit over the top of the boiler water jacket, passing
the tube under the control panel and across the
front of the boiler. Locate the end of the tube over
the burner air supply spigot and secure using the
clamp previously removed.
Clip the tube into the hanging bracket on the flue
elbow so that it does not touch any hot flue parts.
Fig. 29
14 Fit the terminal guard over the flue terminal and
secure using the screws and plugs supplied. See
Fig. 30.
15 Complete the water connections. Refer to section 4.1.
16 Fill the heating system with water and check for
leaks, rectifying where necessary. Refer to section
5.2 to fill the system.
Fig. 30