Technical data
Page 65 
1. FIT DIVERTER ASSEMBLY SEALS 
Apply suitable lubricant to the two Diverter 
Assembly Seals (supplied loose) then fit to 
the  end  of  the  boiler  flue  pipe  noting  the 
correct orientation. 
The  seals  MUST  be  fitted  as  shown  with 
the  outer  surface  sloping  away  from  the 
end  of  the  pipe  to  allow  the  Diverter 
Assembly to push over the seals. 
2. FIT SPLIT RING-NUT 
Fit  the  Split  Ring-nut  by  pulling  open  the  split  and 
pushing the nut over the pipe. Ensure the threaded 
end is facing towards the seals. 
3. FIT & SECURE DIVERTER ASSEMBLY 
Lubricate  the  inside  of  the Diverter  Assembly „B‟ 
then  push  the  assembly  onto  the  end  of  the  pipe 
and  over  the  2  seals.  Use  the  Split  Ring-nut  to  force 
the seals into the assembly ensuring that they remain 
flat on the pipe. 
Tighten  the  Ring-nut  into  the  assembly  ensuring  the 
assembly is tight onto the end of the pipe and that the 
seals  are  well  compressed.  The  Diverter  Assembly 
should be firmly attached to the pipe when complete. 
4. ADJUST DIVERTER ASSEMBLY 
Turn the 90° bend on the Diverter Assembly „B‟ around 
to  45°,  pointing  towards  the  wall.  If  necessary,  adjust 
the  position  of  the  rubber  dresser  on  the  Diverter 
Assembly in order to ensure a good weather seal. 
5. ASSEMBLE PLUME MANAGEMENT KIT 
Assemble the remainder of the Plume Management Kit 
as shown over the page, securing the whole assembly 
into place using the Mounting Brackets „E‟. 
It will be necessary to cut one of the Extensions „F‟ to form Short Extension „C‟, 
depending on the spacing of the boiler from the wall. 
If  fitting  the  flue  extension  pipe  (on  a  150HE  or  Combi  model),  glue  the  rubber 
dresser of the Diverter Assembly „B‟ to the boiler casing using silicone sealant in 
order to secure the assembly in place. 
Ensure the location of the terminal complies with all local legislative requirements. 