Technical data
Page 59 
CONNECT 1
ST
 EXTENSION AND AIR HOSE 
4. Lubricate then fit the 1st extension and secure with the locking band. 
5. Fit the air inlet spigot and gasket to the burner. Attach the flexible air hose to 
the burner and starter assembly and secure with the jubilee clips. 
MEASURE AND CUT TERMINAL 
6. Fit the flashing and assemble the flue up through 
the roof, lubricating  all seals. Measure  the  excess 
length,  X,  noting  carefully  the  correct  measurement 
locations. 
7. Cut X mm from the outer pipe of the terminal (C) 
then  X  mm  from  the  inner  pipe.  Refit  and  secure  in 
place with the bracket (D). 