Technical data
Page 4 
1.4  System Pressure – System & Combi Boilers 
When the boiler is connected to a sealed system the 
system pressure should be periodically checked. The 
minimum pressure, as indicated by the black needle, 
is 0.5  bar  when the boiler  is cold and  2.5  bar when 
the  boiler  is  at  normal  operating  temperature.  If  the 
pressure  is  outside  this  range  contact  Warmflow  or 
your installer. 
1.5  Filling Loop 
If  the  system  pressure  falls  below  the  minimum 
(e.g.,  due  to  the  removal  of  a  radiator  for 
decorating purposes) then the system should be 
topped  up  using  the  filling  loop  valve.  After  the 
system has been topped up the pressure gauge 
should read 1 bar when the system is cold. The 
valve must be fully closed and the flexible filling 
loop  removed from  the  valve,  expect  a  small 
water loss from the pipe. 
Special  attention  must  be  given  to  the 
concentration of corrosion inhibitors in the system water where there is a need for 
topping  up.  Concentrations  must  be  restored  to  inhibitor  manufacturers‟ 
recommendations and monitored going forward. 
Frequent or  routine topping  up of the system should  not be necessary and may 
prove harmful to the appliance. Should topping up prove necessary on a frequent 
or routine basis you must contact Warmflow or your installer. 
1.6  Combi Control Panel 
The heating control thermostat is user adjustable from 50°C to 80°C. In order to 
provide an additional level of safety there is a high limit thermostat which has a cut 
off  point  of  110°C;  this  is  factory  set  and  is  not  adjustable.  The  high  limit 
thermostat is located under the control panel to the left hand side, press button to 
reset.  As  standard the panel  is  fitted with two on/off  selector  switches to control 
hot water and central heating. These switches can be replaced by the optional two 
channel  digital  programmer,  instructions  for  use  are  provided  in  the  main  boiler 
handbook. 
This boiler must be serviced annually. Contact Warmflow for further details. 
In  the  event  of  a  breakdown  please  contact  your  commissioning  engineer  who 
should  then  contact  our  service  department  whilst  at  your  home,  to  report  the 
fault. 
Filling Loop Ball Valve 
System Pressure 