Technical data
Page 3 
1  USER INSTRUCTIONS 
1.1  Dual Thermostat 
The  radiator  temperature  is  regulated  via  the  boiler 
control  thermostat.  The  thermostat  is  user  adjustable 
from 45°C at its minimum setting (dial „0‟) to 75°C at its 
maximum  setting  (dial  „5‟).  In  order  to  provide  an 
additional level of safety there is a high limit thermostat 
which  has  a  cut  off  point  of  110°C;  this  is  factory  set 
and is not adjustable. If thermostat trips it needs to  be 
reset manually. 
1.2  High Limit Thermostat Reset 
If  the  high  level  thermostat  trip  has  operated, 
remove  the  reset  cover  by  using  a  coin  or 
screwdriver  (turning  anti  clockwise)  and  press 
the  small  red  button  now  exposed.  Do  not 
press the reset button while the boiler is still hot 
as this will cause damage to the thermostat. 
1.3  Burner Lockout 
When  the  pressure  jet  oil  fired  burner  stops  after 
failing to fire the red reset button will be illuminated. 
This indicates that there is a fault or there is no fuel 
getting to the burner. The house holder should only 
reset  the  burner  twice  in  succession.  If  the  burner 
continues  to  lockout  contact  Warmflow  or  your 
service engineer. 
Control dial 
Reset button 