Specifications

Page 8
1.4 Baffle Positioning
The primary heat exchanger baffles consist of one
heavy baffle stack (4mm thick) at the bottom, 3
lighter baffle stacks (3mm thick) in the middle and 1
baffle plate (3mm thick) at the top. Upon installation
or after servicing, ensure the baffles are in the correct
order and correctly stacked. To achieve maximum
efficiency push the primary heat exchanger baffles in
the direction of the arrows as shown. The secondary
heat exchanger spring baffles must be fully inserted
into the heat exchanger tubes (narrow end first).
The primary heat exchanger baffles consist of two
half-width baffle stacks at the bottom, 3 full-width
baffle stacks in the middle and 1 baffle plate at the
top. Upon installation or after servicing, ensure the
baffles are in the correct order and correctly stacked.
To achieve maximum efficiency, push the primary
heat exchanger baffles in the direction of the arrows
as shown. The secondary heat exchanger spring
baffles must be fully inserted into the heat exchanger
tubes (narrow end first).
Models up to 120 HE 150 HE Models