Technical data

2.6 Technical Data
Model
Nominal heat KW
Input Btu/hr
Nominal heat KW
Output Btu/hr
Efficiency at max output (net) %
Burner
Head
Flue mm
Size in
Max CO
2
%
Smoke
FGT at max output °C
Water resistance at 20°C T mbar
Approx fuel l/h
Flow rate gals/h
Nozzle make
(kerosine) size
Pump bar
Pressure psi
Nozzle make
(gas oil) size
Pump bar
Pressure psi
Dry weight kg
Primary water content L
Min inlet dynamic pressure bar
for max hot water flow psi
Max DHW flow rate achievable
(refer to page 1)
Factory set DHW flow rate
Min DHW flow rate
DHW temp rise °C
Pressure Relief
Heating flow
Heating return
DHW outlet
Cold water mains inlet (refer to page 1)
Ingress Protection
70/90 Combi
29.3
100,000
26.4
90,000
90
RDB 1
LD3
100 or 127
4 or 5
11.5-12.0
0-1
235
12.0
3.15
0.69
DANFOSS 60°S
0.75
8
116
DANFOSS 60°S
0.6
12
175
155
70
1.8
26
Unrestricted
24 l/min (5.3 gals/min) recommended
18 l/min (4.0 gals/min)
2.5 l/min (0.55 gals/min)
32°C @ 24 L/min for 120L draw off
3 bar (43.5 psi)
22 mm
1” BSP
22 mm
Unrestricted 15 mm bore (minimum)
IPX0
70/90 Kabin Pak Combi
29.3
100,000
26.4
90,000
90
RDB 1
LD3
Integral
Low Level
11.5-12.0
0-1
235
12.0
3.15
0.69
DANFOSS 60°S
0.75
8
116
DANFOSS 60°S
0.6
12
175
155
70
1.8
26
Unrestricted
24 l/min (5.3 gals/min) recommended
18 l/min (4.0 gals/min)
2.5 l/min (0.55 gals/min)
32°C @ 24 L/min for 120L draw off
3 bar (43.5 psi)
22 mm
22 mm Comp.
22 mm
Unrestricted 15 mm bore (minimum)
IP45
Page 13