Installation Guide
3
buywarmall.com
25-year limited Cable Warranty and 2 years on thermostat
WarmAll warrants the heating cable for a period of 25 years and the thermostats (Mysa,
Warmup and OJ Electronics) for a period of 2 years. This Limited Warranty will only be valid
if the installer has followed the approved installation guides of the cable & thermostat, has
completed all the approved installation procedures, conducted all the cable conductivity
/ resistivity test, complete the Test Log Sheet and has complete and sent to WarmAll the
warranty card. See WarmAll’s warranty for details.
Safety and Warnings / Important Information
- If the cable system is damaged, it must be replaced. Do not attempt to connect or repair
part of the system;
- The heating cable must be at least 6“(15cm) away from any heat source;
- lnstall the cable if the temperature is above 40° Fahrenheit or 5° Celsius;
- If you are using the cable with plastic cable guides, the approved spacing are 3, 4 and 5
inches, 4 inches being the standard;
- If you are using a membrane (DrexMat, Prodeso-Heat, MAPEI, Ditra-Heat, Warmup, Prova-
Heat, Laticrete, Nuheat), the spacing approved are: 2 and 3 alternating spacing between
slots, 3 slot spacing, 3 and 4 alternating spacing between slots, 4 slot spacings. 3 slot
spacing is standard;
- If you use Flextherm’s Flexnap-XL membrane, the gap is at the 3-cell spacing;
- Never power the cable if it is on the spool;
- The cable must have a grounding system;
- Never install a cable designed for a 120V power source on a 240/208V power source;
- The system should not be installed under stationary furniture where air is not circulating;
- The cable must never be installed over an expansion joint;
- Do not install this product if the cable seal has been broken;
- The cable system must not extend beyond the room or area in which it is initially installed;
- The cable must be installed at least 2“ from the base of a countertop;
- The cable must be installed at least 2“ from any wall;
- The cable must be installed at least 6“ from any type of drain;
- The cable cannot be overlapped, cut or modied;
- The entire heating part of the cable (including the connection) must be fastened to the
oor and covered with thinset cement or self-leveller;
- The heating cable must never be installed in/on walls;
- The cable must never be submerged;
- The suboor must meet or exceed the C.N.B. requirements or any other regulations in
your area. Refer to the membrane manufacturer or the Tile Council of Canada North
America.
IMPORTANT
Perform ail initial cable tests checks without unsealing the cable.
If all the tests prove successful, follow the installation guide.
General information