Installation Guide

15
buywarmall.com
Installation with Plastic Cable Guides
IMPORTANT
Do not cut or shorten the cable. Do not expose it to mechanical stress. Avoid walking
on the heating cable. Wear shoes with soft soles.
lnstallation/Technical information
Cable without magnetic eld
Model
Length
Spacing (ft
2
)
Watt Amp Ohms Guides
3" 4" 5"
Ft.
M 14.8 W 11.1 W 8.9 W
3,7GCWC-120V-05 16.5 5.05 4.1 5.5 6.9 60 0.5 240.0 10
3,7GCWC-120V-10 33.0 10.1 8.3 11.0 13.8 120 1.0 120.0 10
3,7GCWC-120V-14 49.5 15.1 12.4 16.5 20.6 180 1.5 80.0 15
3,7GCWC-120V-19 66.0 20.1 16.5 22.0 27.5 240 2.0 60.0 20
3,7GCWC-120V-24 82.5 25.1 20.6 27.5 34.4 300 2.5 48.0 20
3,7GCWC-120V-29 99.0 30.2 24.8 33.0 41.3 360 3.0 40.0 20
3,7GCWC-120V-34 115.5 35.2 28.9 38.5 48.1 420 3.5 34.3 30
3,7GCWC-120V-38 132.0 40.2 33.0 44.0 55.0 480 4.0 30.0 30
3,7GCWC-120V-43 148.5 45.3 37.1 49.5 61.9 540 4.5 26.7 30
3,7GCWC-120V-48 165.0 50.3 41.3 55.0 68.8 600 5.0 24.0 40
3,7GCWC-120V-58 198.0 60.4 49.5 66.0 82.5 720 6.0 20.0 40
3,7GCWC-120V-67 231.0 70.4 57.8 77.0 96.3 840 7.0 17.1 50
3,7GCWC-120V-77 264.0 80.5 66.0 88.0 110.0 960 8.0 15.0 50
3,7GCWC-120V-87 297.0 90.5 74.3 99.0 123.8 1080 9.0 13.3 60
3,7GCWC-120V-96 330.0 100.6 82.5 110.0 137.5 1200 10.0 12.0 60
3,7GCWC-120V-106 363.0 110.6 90.8 121.0 151.3 1320 11.0 10.9 60
3,7GCWC-120V-115 396.0 120.7 99.0 132.0 165.0 1440 12.0 10.0 70
3,7GCWC-120V-125 429.0 130.8 107.3 143.0 178.8 1560 13.0 9.2 70
3,7GCWC-120V-135 462.0 140.8 115.5 154.0 192.5 1680 14.0 8.6 80
3,7GCWC-120V-144 495.0 150.9 123.8 165.0 206.3 1800 15.0 8.0 80
Cable 3.7 Watts 120 Volts
Ft = feet
Ft
2
= square feet
M = meter