Installation Guide
13
buywarmall.com
Installation with Plastic Cable Guides
Heating cable
Hot Glue Nails Staples
IMPORTANT
Initial cable and sub-oor verication procedures are outlined on page 17 to page 20.
Read and understand them carefully before installing. If you have any questions, please
contact WarmAll.
Installation with Plastic Cable Guides Instructions
Attach the cable guides to the suboor, perpendicularly to the direction of the cables, with
screws hot glue, staples, nails or double-sided adhesive tape.
• 3 inch spacing = 14.8W per sq.ft.
• 4 inch spacing = 11.2W per sq.ft.
• 5 inch spacing = 8.8W per sq.ft.
• Optimum and/or standard spacing is 4 inches
The elaboration of a oor plan is essential before laying the cable on the oor.
This will help visualize the layout. All WarmAll cables must be installed with a regular spacing
of 3, 4 or 5 inches, 4 inches being the standard and are available in the 120V or 240V.