Installation Guide

10
buywarmall.com
Installation with an Uncoupling Membrane
lnstalling the cable
After carrying out the rst cable resistance and insulation tests and conrming that the
reading are good, (note: write the results in the Test Log Sheet) install the connection part
of the cable (connecting the heating part to the black non-heating cable) in accordance with
the instructions of the membrane manufacturer and run the non-heating cable through the
wall to the thermostat. Start installing the cable in the membrane per instructions.
Example of wire installation on the oor
Total area 96 sq. ft. minus 22 sq. ft. of xed furniture space equal heated area 74 sq. ft.
Using the specications and calculation of the total area to be heated, you can choose
the appropriate cable size. Dene the optimal layout of the oor to be heated using the
WarmAll disposition Help Matrix (www.BuyWarmAll.com) to ensure adequate coverage.
IMPORTANT
Do not cut or shorten the heating cable. Do not expose it to any mechanical stress.
Avoid walking on the heating cable. Wear shoes with soft soles.
8 ft
9 ft
3 ft²
10 ft
12 ft
16”
16”
²
2”-3”
Thermostat