Instruction Booklet

7
INSTALLATION
Carefully remove the pasta cooker from the packaging and place the
unit on a rm, level surface.
Insert the basket hanger into the two holes in
the brackets, located in the rear of the unit.
Use only the baskets provided with the unit.
DO NOT substitute the baskets or attempt
to replace the baskets.
This unit is to be installed with adequate backow protection to comply
with applicable federal, state, and local codes.
This unit can also be used as a stand-alone, without external plumbing
connections.
STAND ALONE INSTRUCTIONS FOR INSTALLATION
Make sure all three valves are in the closed position. There are two
located in the front of the unit and one located on the back of the
unit. Fill unit with a bucket of tap water up to the ll line (just below
the overow drain).
PLUMBED INSTRUCTIONS FOR INSTALLATION
Connect to the rell (located on back of pasta cooker) and overow
plumbing connections.
The rell plumbing connection is a male NPT ½ x 12. The overow
plumbing connection is a female NPT ½ x 12.
If connecting to an outside water line, the plumbing connections must
contain water pressurized at or below Water Line Pressure and at or
below 40˚C (10F) during normal operation. If using a rubber hose:
It must have a Reinforcing Outer Braid, and have a manufacturer’s
rating of at least 200 psig.
Make sure the water overow outlet valve (located on back of pasta
cooker) is in the open position. Open the water rell valve (located
on the front of the pasta cooker) to ll the basin with water. The valve
can be adjusted between open and close positions to control the
water ow into the basin.
FRONTBACK
Rear of Unit