• Cleanandsanitizemotorbasepriortoinitialuseandaftereachuse.
• Washingsolutionsbasedonnon-sudsingdetergentsandchlorine-based
sanitizingsolutionshavingaminimumchlorineconcentrationof100PPM
are recommended.
Thefollowingwashing,rinsing,andsanitizingsolutionsortheirequivalents
may be used.
SOLUTION PRODUCT DILUTION IN WATER TEMPERATURE
Washing DiverseyWyandotte 4tablespoons Hot115˚F(46˚C)
DiversolBX/aorCX/A /gallon
Rinsing PlainWater Warm95˚F(35˚C)
Sanitizing Clorox
®
1tablespoon/gallon Cold50-70˚F
InstitutionalBleach (10-21˚C)
• Inrepetitivebatch-processingapplications,frequentcleaningofthecon-
tainerwillprolongthelifeofthebladeassembly.Innocaseshouldactual
runningtimebetweencleaningsexceedone-halfhour.
• Donotusecontainertostoreprocessedfoodsorbeverages.
To Wash and Rinse Container
1. REMOVECONTAINERFROMMOTORBASE.Removelid.Rinse
container interior and lid under running water. Add washing solution to
container. Scrub and flush out the container interior and lid to dislodge
and remove as much food residue as possible. Empty container.
2. Wipedownexteriorofcontainerwithasoftclothorspongedampened
with washing solution. NOTE:Bladesaresharp.Handlecarefully.
Washlidandlidinsertinfreshwashingsolution.Fillcontainerone-quarter
full with fresh washing solution, cover, place on motor base, and run on
high speed for one (1) minute. Empty container.
3. Repeat step (2), using clean rinse water in place of washing solution.
IMPORTANT
INORDERTOMINIMIZEPOSSIBILITYOFSCALDING,TEMPERATURE
OFWASHINGSOLUTIONANDRINSEWATERMUSTNOTEXCEED115°F
(46°C),ANDQUANTITYUSEDMUSTNOTEXCEEDONE-QUARTER
CONTAINERFULL.
IFHIGHERTEMPERATURESORLARGERQUANTITIESAREUSED,
OBSERVEALLPRECAUTIONSGIVENINTHEOPERATINGMANUALUNDER
“HOTBLENDINGINSTRUCTIONS”,page8.
To Sanitize and Dry Container
1. Wipedownexteriorofcontainerwithasoftclothorspongedampened
withsanitizingsolution.
2. Fillcontainerwithsanitizingsolution,cover,placeonmotorbase,and
run on high speed for one (1) minute. Empty container. Dislodge any
residual moisture from blade assembly by placing empty container on
motor base, and running on high speed for two (2) seconds.
3. Sanitizelidandlidinsertbyimmersinginsanitizingsolutionfortwo
(2) minutes.
4. Donotrinsecontainer,lid,orlidinsertaftersanitizingiscompleted.
Allow parts to air dry.
To Clean and Sanitize Motor Base
1. UNPLUGPOWERCORD.Wipedownexteriorsurfacesofmotorbase
with soft cloths or sponges dampened with washing solution, rinse
water,andsanitizingsolution.Preventliquidfromrunningintomotor
basebywringingallexcessmoisturefromclothsorspongesbefore
using them.
DONOTIMMERSEMOTORBASEINWASHINGSOLUTION,RINSE
WATERORSANITIZINGSOLUTION.
2. Allow motor base to air dry before using.
Anyotherservicingshouldbeperformedbyanauthorizedservice