Installation Guide
Table Of Contents
Fig. 1
PHOTOCELL INSTALLATION
1. Install photocell and wire as per diagram.
2. Use photocell rated for your supply voltage.
1. Check that the line voltage at the fixture is correct.
Refer to wiring directions.
2. Is the fixture grounded properly?
3. Be sure the photocell, if used, is functioning properly.
TROUBLESHOOTING
ON-OFF WIRING
Universal voltage driver permits operation at 60 Hz except fixtures
factory ordered with a 120-277VAC (P0) or 347VAC photocell (P3)
1. Connect the BLACK fixture lead to the (+) LINE supply lead.
2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
3. Connect the Yellow Green wire from fixture to supply ground.
CLEANING & MAINTENANCE
CAUTION: Be sure fixture temperature is cool enough
to touch. Do not clean or maintain while fixture is
energized.
1. Clean glass lens with non-abrasive glass cleaningsolution.
2. Do not open the fixture to clean the LED. Do not touch the LED.
BLACK
BLACKBLACK
AC
INPUT
LAMPLOAD
RED
PHOTOCONTROL
WHITE
WHITEWHITE
Black
White Neutral
Green/Yellow Green
Ground
Line
Purple
DIM+
Gray
DIM-