Operating Instructions and Installation Instructions

23
GB
Technical details Square
Technical details 60 68 75
Door latch Ba I/II Ba I/II Ba I/II
Nominal capacity* 6 kW 7 kW - kW
Diameter tube for combustion gases 150 mm 150 mm 150 mm
Maximum lumber supply in the stove 3 kg 3 kg 3 kg
Maximum brown coal supply -- kg -- kg -- kg
Volume of the combustion chamber 0,03 m3 0,05 m3 0,07 m3
Surface bottom of combustion chamber 0,11 m2 0,13 m2 0,15 m2
* the nominal heat is obtained with a chimney draught of 0.12 mbar
Fuel, wood logs, 30 x 10 cm
Maximum supply 3 pieces
Primary air valve max.
Secondary air outlet max.
Fuel burning period about 1 hour
Flue gas values in accordance with DIN 4705, DIN 18895 part 2
Square 60 68 75
When door is closed logs logs logs
Flue gas quantity 6 g/s 7,3 g/s - g/s
Flue gas temperature 335 ˚C 335 ˚C - ˚C
Pre-pressure 0.12 mbar 0,12 mbar 0,12 mbar
Yield 78,4 % 79,0 % - %
CO at 13% O2 0,10 % 0,09 % - %
Particulate matter 1250 mg/m3 1125 mg/m3 - mg/m3
Certificate Institute 1625. Test standard EN 13229. Test report no. RRF-29 09 1895 (Square 60)
RRF-29 09 2028 (Square 68)
RRF- (Square 75)