Gas connection
• Use a feed pipe with an approved G3/8” stop cock with coupling.
• De-aerate the supply pipe before  tting and fastening the appliance.
• Avoid all tension on the operating valve and pipes to avoid gas leakage.
• Check if the connection is gastight.
Placing of the concentric  ue system
The concentric channel system consists of three parts: the channels itself, the transit through the roof or
through a wall and the out ow. The diameter for the  ue pipes of the Square is 100/150 mm.
Instructions for placing the outlet
The out ow of the pipe system can be placed on top of the roof or against the side wall of the house.
Roof outlet
When placing the out ow on top of the roof, make sure that there is a distance of at least 50 cm between the
out ow and the edges of the roof, with the exception of a possible existing ridge. You must also take the place
of the out ow into account in relation to the existing ventilation openings, movable windows and combustion
air supply provisions. Please consult the national and local requirements.
Wall outlet
When placing the out ow into the side wall, make sure that there is distance of at least 50 cm between the
out ow and the corners of the building, eaves, gutters, balconies and etcetera. You need not have this distance
when the out ow runs through to at least the front of the overhanging part.
You must also take the place of the out ow into account in relation to the existing ventilation
openings, movable windows and combustion air supply provisions. Please consult the national and
local requirements.
Placing possibilities of the  ue system
The total length of the pipe system must never be more than 10 metres excluding the passage through the
wall and the out ow. A 90° square angle counts as a length of 2 metres. A 45° turn counts as a length of 1
metre.
For the combined  ue tube and combustion air supply you must apply one of the shown placing possibilities
of the WANDERS concentric pipe systems: with wall duct, with roof duct or with roof duct with bend.
!