Lighting the appliance
For best results set air controls
primary air open and air wash
completely open
Place firelighters and two hands full
of dry kindling wood on the grade
Light the firelighters,
Leave the door slightly open as the
fire establishes and the glass warms
to avoid buildup of condensation.
after several minutes the fire bed is
dying back at this point you place
lager pieces of wood on the fire approximately 1 kg leave the air controls unaltered when
these logs are well alight place two more logs onto the fire approximately 1,4 kg the air
controls and the door being in the same position as before after about 20 minutes from the
start close the door and primary air control.
Do not overload the fire ensure that the top of the logs are no higher than and do not obstruct
the rear holes the maximum amount of fuel specified in this manual should not be exceeded
overloading can cause excess smoke
Close the door do not leave the door open as this could over-fire and damage the appliance.
Refueling
after refueling set the door on the
latch but not closed. the primary
air set fully open and the
secondary air set in the required
position after 5 minutes when the
logs are burning well close the
door and the primary air supply.
If there is insufficient burning
material in the firebed to light a
new fuel charge, excessive smoke
emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new
fuel charge will ignite. If the fire bed is too low or cool, suitable kindling must be use
to relight fires.
Operation with the door open can cause excess smoke. The appliance must not be operated
with the appliance door left open except as directed in the instructions.
Air controls left open
Operation with the air controls open can cause excess smoke. The appliance must not be
operated with air controls or dampers door left open except as directed in the instructions