The flue or chimney system must be in good condition.
It must be inspected by a competent person and passed for use with the appliance before installation
Products of combustion enteringthe room can cause serious health risks.
You must check the following:
The construction of the masonry chimneys, flue block chimneys and connecting flue pipe system must
meet the requirements of the Building Regulations
A flexible flue liner system certified for use with solid fuel systems and installed to manufacturer’s
instructions and Building Regulations should be used.
Theflue liner must be replaced when an appliance is replaced unless proven to be recently installed
and in good condition.
The minimum height of the flue or chimney must be 4.5m from the hearth to the top of the flue, with no
horizontal sections, a maximum of 3 bends with angles of less than 45 degrees
Ensure the connecting flue pipe is kept a suitable distance from any combustible material and does
not form part of the supporting structure of the building
Make provision to remove the appliance without the need to dismantle the chimney
Any existing flue must be confirmed as suitable forthenew intended use as defined in the Building
Regulations.
The flue or chimney systems must be inspected and swept to confirm the system is structurally sound
and free from obstructions.
If the appliance is believed to have previously servedan open fire the chimney must be swept a
secondtime within a few months of regular use after installation to clear any soot falls that may
occurred due to difference in combustion levels.
The flue exit from the building must comply with local building control rules.
Do not connect or share the flue or chimney system with another heating appliance
You must sweep and inspect the flue when the appliance is installed.
You must check the flue draught with all windows and doors closed and any extraction fans in this or
adjoining rooms running at maximum speed.
Max. Draught = 2.0mm Wg
Min. Draught = 1.5mm Wg