Operating Instructions and Installation Instructions

15
Technical specification
Nom heat
output
efficiency
CO emission
At 13% O²
Flue gas
temperature
Flue gas
Mass flow
Wood 4,8 kW 78,1% 0,27% 258ºC 4,5 g/s
Ancit 4,5 kW 70,8% 0,04% 318ºC 4,1 g/s
Distance from combustibles Shelf 575 mm
Side 300 mm
Refuelling interval Wood Ancit
1 h 1 h
mass of the Marvic 65 kg