Operation Manual
26
Gastype A (min.-max.) B (min. - max.) Collar shaft Gastype A (min. - max) Collar shaft
Nat. gas
LPG
Butane
1,0 - 3,0 m 0 - 0,5 m Ø 70 mm
Ø 80 mm
Ø 80 mm
Nat. gas
LPG
Butane
5,0 - 10,0 m Ø 50 mm
Ø 50 mm
Ø 50 mm
Nat. gas
LPG
Butane
1,2 - 3,0 m 1,0 - 3,0 m NO
NO
NO
Nat. gas
LPG
Butane
1,0 - 5,0 m Ø 70 mm
Ø 70 mm
Ø 70 mm
all dimensions are exclusive the length of the wall outlet all dimensions are exclusive the length of the roof outlet
Gastype B (min. -
max.)
A1 (min. -
max.)
A1 + A2
(min. - max.)
Collar
shaft
Nat. gas
LPG
Butane
1 - 3 m 1 - 10 m 1 - 10 m NO
NO
NO
(A1 + A2 : B) : 1 Proportion vertical: horizontal (or 45
o
up)
is always at least 2 : 1
all dimensions are exclusive the length of the roof outlet
Wall outlet
t Always allow one metre vertical before passing through the outer wall.
t The maximum length for a horizontal segment is 3 metres.
t Determine the location of the appliance and the exterior wall duct.
t Make an opening of Ø 160 mm for the wall duct.
t Connect the wall duct vertically with a curve to the mouth of the appliance, push them rmly together and
place the clip binding. The blue rubber ring ensures sucient sealing of the outlet of the ue gas system.
t If the appliance is placed more than 1 meter from the outside wall, place the rst meter on top the appli-
ance, then the elbow followed by the wall outlet. Finally make sure the construction is gastight.
A
A
B
A1
A2
B