Operation Manual
20
Ifthereinthegashearthhasgoneoutyoumustwaitatleast10minutesbeforereignitingthe•
gasstove(checkthesectionon‘puttingthereplaceintooperation).
Toensuresafeandcorrectoperationofthereplaceitisadvisabletohaveitcheckedandcleaned•
byacertiedinstalleratleastonceayear.
Ifthereinthereplaceextinguishedrepeatedlyyoumustconsultyourinstaller.•
The front side of the stove is regarded as the heat exchange surface.•
Caution: do not burn the stove if the glass window is broken or if the door of the stove is open. •
Have the hearth repaired only with original parts supplied by the manufacturer, and have the •
repairscarriedoutbyacertiedinstaller.
Do not alter or add anything to the log set under any circumstance. If a log is broken it must be •
replaced by an original log that is supplied by the manufacturer.
Toeliminateanypossibleriskofre,thedistancebetweenthecombustiblepartsandthefurniture•
must be at least 100cm, and the distance between the rear side of the stove and the wall must
be at least 20cm.
Itisimportantthatyoudonotusethereplaceshortlyafterrenovationorinanewlybuilthome;•
the air circulation draws in moisture and unhardened volatile elements of plaster, paint, oor
coverings and other materials. This can cause soot stains on cold surfaces.
3.5 TTB Safety device
Thereplaceisequippedwithathermalreuxsafetyvalve(TTB),atemperatureswitchthatbecomes
operativewhenthechimneydoesnotdrawwellanduegassesentertheroom.Whenthishappens,
the unit will conk out.
Caution: Never put the TTB out of operation. When the TTB is defect, you must replace it with
original parts.
When the TTB safety mechanism has shut off the stove, you must wait at least 10 minutes before
lightingthereplaceagain.Iftheburnerconksoutrepeatedly,youmustconsultaninstaller.
Caution: Do not use the replace until the qualied installer has given the go-ahead.
3.6 Operating the replace for the rst time
Whenlightingthereforthersttime,anunpleasantscentmaydevelopcausedbythehardeningofthe
heat resistant lacquer on the stove. The scent will disappear after several hours. We therefore advise
youtoburnthestoveatitshighestcapacitywhenyoulightupthereforthersttimewhileventilating
the room in which the stove is installed.
3.7 Maintenance
In order to ensure the safe and correct operation of the replace, the stove must be checked and
cleanedbya qualied professional every year.Theserviceshould include the burner unit, the pilot
ameandthecombustionchamber.
The ceramic glass can be cleaned with a special cleaning agent for ceramic cookers.
If a log is broken it must be replaced.
If there is a crack in the glass window, or if the window is broken, it must be replaced before operating
the gas hearth.
When the logs are replaced, ensure that they are placed in the correct position (see the chapter on the
log set).