Operation Manual

26
Technical details
Basic
Door latch I & II Ba
Nominal capacity* 6 kW
Fleu collar diameter 150 mm
Maximum load capacity 3 kg
* the nominal heat is obtained with a chimney draft of 0,12 mBar
Fuel, wood logs (30 x 10 cm)
Maximum supply capacity 3 pieces
Primary air valve maximum
Secundairy air outlet maximum
Fuel burning period about 1 hour
Flue gas values in accordance with DIN4705, DIN 18895 part 2
Basic
Flue gas quantity 6,0 g/s
Flue gas temperature 335
0
C
Pre-pressure 0,12 mBar
Eciency 78,4 %
CO at 13% O
2
0,10 %
Particulate matter 28 mg/m
3
Certicate institute 1625
Test standard EN13229
Test report number RRF - 2909 1965
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be
taken for the volume of the space to be heated:
If heating circumstances are favourable:
In less favourable circumstances:
In unfavourable circumstances:
calculate according to DIN 4701
90 m
3
70 m
3
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is
more than 8 hours.