test certificate
IMQ
primacontrol
Manufacturer
Type
Model
Testreport
No.
WAMSLER
SE
WP2-8 ; WP2-8K; WP2-8 A ; WP2-8K A
CPR-13-010
Technical
data - Nominal heat output
Dali
tecnici - Potenza termica nominale
Type designation
Type:
----- -----
Tipo:
Model:
WP2-8
WP2-8K
Mode/lo:
Appliance type
Appliance type:
Pellet stove
Pellet stove
Tipo di apparecchio:
The appliance can be connected to a share chimney:
Yes
Yes
L 'apparecchio pu6 essere installato su canna condivisa:
Operating tool supplied:
Yes
Yes
Dotato di altrezzo di funzionamenlo:
Options:
Witht forced Without forced
Opzioni:
ventilation ventilation
Fuel
type:
Wood
pellet Wood pellet
Tipo di combuslibile:
Key data of the appliance at nominal heat output
Fuel hourly consumption
kg/h 1,9 1,6
Consumo orario
Necessary flue draught
Pa
11
10
Requisiti minimi de/ tiraggio de/ camino
Flue gas temperature
oc
181
195
Temperatura fumi
Flue gas temperature at flue spigot or socket
oc
202
226
Temperatura uscita fumi
Flue gas mass flow
g/s 7,0 5,9
Flusso massico dei fumi
Efficiency
%
86,0 85,5
Rendimenlo
Total heating output
kW
7,5 6,5
Potenza termina nominale totale
Waier heating output
kW
----- -----
Potenza termica resa a/l'acqua
Space heating output
kW
-----
-----
Potenza termica resa a/l'ambiente
Maximum water operating pressure
bar
----- -----
Massima pressione di esercizio de/l'acqua
Discharge control operating temperature
oc
----- -----
Temperatura di intervento valvola scarico termico
EN
14785:2006 Rev.4
Notified Body
No.
1881
Ente Notificato
n°
1881
Date 2013/10/13
Test engineer Dino Grotto
-----
----- -----
WP2-8 A WP2-8K A -----
Pellet stove Pellet stove
-----
Yes Yes
-----
Yes Yes
-----
Witht forced
Without forced
-----
ventilation ventilation
Wood pellet Wood pellet Wood pellet
1,9
1,6
-----
11
11
-----
146 144
-----
163 166
-----
6,2
5,7
-----
90,5
90,0
-----
7,5
6,5
-----
----- ----- -----
-----
-----
-----
-----
-----
-----
-----
----- -----
Page 2
of
90