1.2 Installation
Fuels
The equipment can be used with fuels detailed in the followings. This way the “low-
smoke” and trouble-free operation can be secured. Use only dry wood with
moisture of maximum 20% and lignite briquette.
Filling quantities 6 kW Filling quantities 8 kW
- Split billet: max. Length: 33 cm - Split billet: max. Length: 33 cm
max. two billets per filling, appr. 1.4 kg max. two billets per filling, appr. 2.0 kg
- Lignite briquette: max. 1.7 kg - Lignite briquette: max. 2.2 kg
Adjustment of the burning air:
primary air
regulator
secondary air
regulator
Setting of the
fuel selector
Fuel
door down
door up
(when existent)
backside
Warming up, kindling 2 - 4 2 H
Wood
Nominal heating
performance
2 2 H
Brown-
coal
Nominal heating
performance
2,5 2 K
Putting out of working
order
0 0 K
Table 1
Device control with the automatic control
When igniting the air control to "hand" and level "2". After about an hour, the air
controller on "automatic", level 5-6. Then you can with the "automatic control"
the desired temperature.
IT IS NOT ALLOWED to burn waste, fine chipping, bark, wood handled with
preventive chemicals, furthermore paper and cardboard. For kindling please use
wood scrapings or grill starter but never use liquid auxiliaries!
The first kindling
At the first fire set-up could be a little smoke, but is not dangerous, normal!
In this time, please ventilate the room carefully!
Types of fuels
Heating value
appr. kJ/kg
Hard wood 19.500
Soft wood 14.600
Brown-coal 11.500