6.5.8 Changing the trigger system
Before changing the trigger system, make sure that the pistol is unloaded and uncocked (see
Section 5.2).
• Dismantle the grip (see Section 6.1.1).
• Undo screws (1) with a 2 mm Allen key
• Remove the trigger system from the housing.
• To install the new trigger system slightly tighten both screws.
• Tighten the right-hand screw and then the left-hand one.
1
NOTE
Check the trigger pull weight after replacing or reinstalling the trigger system. It may
have changed slightly.
Figure 19