5. Introduction, Product Features and Specifications
Introduction
This alarm detects products of combustion using photoelectric technology and carbon monoxide using an electro-
chemical cell. Many times throughout this User Guide, we will refer to Carbon Monoxide as “CO.” Ten (10) years after the
unit was installed, this unit will automatically alert you that it is time to replace the unit. This is called “End of Unit Life”
mode. See Troubleshooting Guide. To help identify the date to replace the unit, a label has been affixed to the side of
the alarm. Write the “Install date” in the space provided, and then write in the “Replace by” date (10 years from initial
power up) in permanent marker on the label prior to installing the unit. NOTE: AC power must be connected to obtain
the full 10 year battery and unit life. Two labels have been provided that have important information on what to do in
case of a CO alarm. Place one label next to the alarm after it is mounted, and one near a fresh air source such as a door or
window.
Product Features and Specifications:
Temperature: Operating Range: 40°F (4.4°C) to 100°F (37.8°C)
Humidity: Operating range: 10-95% RH non-condensing
Audible Alarm: 85+ dB at 10’ 3.0 to 3.5 KHz pulsing alarm, with voice messages
“Fire!” and/or “Warning! Carbon Monoxide.
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Voice message system
Smoke Alarm SMART HUSH® Control
Ambient Light Sensing
Powered by 120VAC (60 Hz, 53 mA max) wire-in connector with sealed lithium battery backup.
Hardwire and wireless interconnectable to other compatible alarms.
One large, user- friendly button.