Owner's manual

19
O.S. Walker Inc., NEO Permanent Lifting Magnets
NEO-1000 LIFTING GUIDELINES
(ROUND BARS & PIPES)
Values shown are for maximum rated capacities when operating instructions and warnings are
followed.
VALUES ARE BASED UPON AISI 1020 STEEL
Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)
NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH
ROUND BAR/PIPE DIAMETER, WALL THICKNESS & TYPE OF SURFACE CONDITION
Round
Bar/Pipe
Diameter
Inches
Pipe
Wall
Thickness
Inches
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000” Max. Air Gap †
RUST OR SCALE
Similar to a Flat Hot
Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
11
(279mm)
MAX. DIAM.
3/8” 31” 117 27” 97 21” 77
1/2” 39” 182 35” 163 30” 141
1” 66” 587 58” 522 50” 449
SOLID BAR 40” 1100 34” 925 26” 720
8”
(203mm)
3/8” 46” 117 38” 97 30” 77
1/2” 54” 182 49” 163 42” 140
SOLID BAR 77” 1100 65” 925 50” 720
6”
(152mm)
3/8” 62” 117 51” 97 41” 77
1/2” 74” 182 67” 163 58” 140
SOLID BAR 137” 1100 115” 925 90” 720
4”
(101mm)
3/8” 96” 117 80” 97 63” 77
1/2” 116” 182 105” 163 90” 140
SOLID BAR 177” 629 177” 629 177” 629
3”
(76mm)
MIN. DIAM.
3/8” 133” 117 110” 97 87” 77
1/2” 114” 127 102” 114 89” 99
SOLID BAR 177” 354 177” 354 177” 354
NEVER LIFT ROUND BARS OR PIPES WITH:
A diameter LESS THAN 3 Inches or
A diameter GREATER THAN 11 Inches or
A wall thickness LESS THAN 3/8” (9.5 mm) or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 177” (4500mm)
Air Gap = nonmagnetic separation between magnet’s lifting surface and load.